48 Core OPGW Optical Ground Wire – NL-OPGW-48B1-90
The NetLast NL-OPGW-48B1-90 is a 48 core G.652 optical fiber composite overhead ground wire with two stainless-steel optical tubes, 118.0 kN rated tensile strength and 44.18 kA²s short-circuit capacity. It combines power-line grounding with reliable utility communications for overhead transmission networks.
Description
48 Core OPGW Optical Ground Wire
The NL-OPGW-48B1-90 integrates 48 G.652 single-mode fibers in two stainless-steel optical tubes with aluminum-clad steel load-bearing wires. Installed in the overhead ground-wire position of high-voltage transmission lines, it supports lightning protection and fault-current transmission while providing a protected optical channel for utility communications, SCADA, teleprotection and grid monitoring.
Key Features
- 48 single-mode G.652 fibers in two stainless-steel tubes, 24 fibers per tube
- Two-layer metallic construction with 20% aluminum-clad steel wires
- 118.0 kN rated tensile strength
- 92.68 mm² supporting cross section
- 44.18 kA²s short-circuit current capacity
- 13.20 mm nominal cable diameter and 661 kg/km nominal weight
- Right-hand outer-layer Z-stranding
- Designed according to DL/T 832 requirements
Technical Specifications
| Parameter | Value |
|---|---|
| NetLast model | NL-OPGW-48B1-90 |
| Cable type | OPGW-2S 2/24 (M93/R118-44) |
| Fiber count and type | 48 × G.652 single-mode fiber |
| Center wire | 1 × 20% ACS wire, 2.60 mm |
| Layer 1 | 4 × 20% ACS wire, 2.50 mm |
| Optical units | 2 × SUS tube, 24 fibers per tube, 2.50 mm |
| Layer 2 | 11 × 20% ACS wire, 2.80 mm |
| Outer-layer stranding direction | Right-hand Z-stranding |
| Cable diameter | 13.20 mm |
| Cable weight | 661 kg/km |
| Supporting cross section | 92.68 mm² |
| ACS / AA wire cross section | 92.68 / 0.00 mm² |
| UTS / RTS pull-to-weight ratio | 19.16 / 18.20 km |
| Ultimate tensile strength (UTS) | 124.2 kN |
| Rated tensile strength (RTS) | 118.0 kN |
| Modulus of elasticity | 162.0 kN/mm² |
| Thermal elongation coefficient | 13.0 × 10⁻⁶/°C |
| Maximum working stress (MAT, 40% RTS) | 509.2 N/mm² |
| Everyday stress (EDS, 15%-25% RTS) | 191.0-318.3 N/mm² |
| Strain margin stress (70% RTS) | 891.1 N/mm² |
| DC resistance at 20°C | 0.931 Ω/km |
| Short-circuit current (0.25 s, 40°C-200°C) | 13.29 kA |
| Short-circuit current capacity (40°C-200°C) | 44.18 kA²s |
| Minimum bending radius – installation | ≥396 mm |
| Minimum bending radius – operation | ≥264 mm |
| Installation tensile strength (≤20% RTS) | ≤23.6 kN |
| Installation temperature | -10°C to +50°C |
| Transportation and operation temperature | -40°C to +80°C |
| Reference standard | DL/T 832 |
Applications
- Overhead ground-wire systems on power transmission lines
- Utility backbone communications and grid monitoring
- SCADA, teleprotection and substation communications
- New transmission-line construction and existing-line upgrades
Custom Engineering and Inquiry
OPGW selection is project-specific. Fiber count and type, metallic cross section, RTS, short-circuit capacity, cable diameter, unit length, applicable standard, fittings and packing can be engineered according to the transmission-line specification.
Send your required fiber count, fiber type, RTS, short-circuit capacity, supporting cross section, standard, project quantity and drum length to receive a technical proposal and quotation.
Related Products
-
Optical Distribution Box
16 Port Fiber Optic Distribution Box with MINI SC/APC Adapter – NL-DBW015
Read more -
Equipment & Accessories & Tool
FTTH Fiber Optic Termination Tool Kit with Power Meter and VFL – NL-TKB02
Read more